Facility details at ATC

//Facility details at ATC

Facility details at ATC

EMC & Radio Test*1  Facilities

*1 : Radio test is available from January 2018

3m Anechoic Chamber (2 rooms)

■ Room size:6 x 9 x 5.5 m
■ Shield size : 7x 10 x 6.3 m
■ Door:2 x 2.5 m (Swing type)
■ Turntable:Diameter 2 m/Weight 1 t
■ EMI:
Frequency:9kHz ~26.5GHz
SVSWR : 6dB and below(1GHz-18GHz)
NSA : Within ±4.0dB(30MHz-1GHz)

 ■ EMS:
Frequency : 80MHz ~ 6GHz
Testing Level:3V/m
■ Standards :
FCC Part 15 Subpart B
EN 55032(22) / CISPR 32(22)(3m Method)
EN 55024 / CISPR 24
EN 61000-4-2 ~ 11
EN 301 489-1 / -3 / -17
EN 55025 / CISPR 25 / EN 50498
ISO11452-2,3,4,5,9 / SAE J1113-25

EMC Anechoic Chamber for in-vehicle devices (4 rooms)

■ Room size :6 x 7 x 3.4 m
■ Shield size :7 x 8 x 4.2 m
■ Door :2 x 2.5 m (Swing type)
■ Detail of Test:
* CISPR 25 : 20Hz – 320MHz(Conducted Test)
:9kHz – 6GHz(Radiated Test)
* ISO 11452-2:200MHz – 6GHz/200V/m
(Radar Pules : 600V/m)
* ISO 11452-3:10kHz – 200(400)MHz
* ISO 11452-4:100kHz – 400MHz(BCI)
(TWC:400MHz – 3GHz)

* ISO 11452-5:10kHz – 1GHz(50Ω)
* ISO 11452-9:28MHz – 6GHz
* ISO 11452-10:15Hz – 500kHz(30Vpp)
* SAE J1113-25:10kHz – 1GHz
*TEM Cell:Septum:300mm
*Strip line:10kHz – 1GHz(200V/m)
*Tri-Plate:10kHz – 1GHz(200V/m)
■ Standards
EN 55025 / CISPR 25 / EN 50498
ISO11452-2,3,4,5,9,10 / SAE J1113-25

Electrical Testing Room (2 rooms)

DC high-voltage power source immunity testing equipment

■ Output voltage/Current: 0 ~ ± 500V / 78A

■ Output frequency: DC ~ 5kHz

Electrical test to ISO 16750-2, LV124, LV148, LV123 etc…

Power Equipment Room

■ High-voltage DC    power supply
(Max. DC500V/160A)
(max. DC1000V/26A)

■ AC power supply
(Max. 8kVA)

■ Electronic load
(Max. 26kW)

■ Power Amplifier
(Max. 1kW)

Shield Room (2 rooms)

■ Shield Surface:5 x 8 x 4.3m
■ Door:(Swing Type) : 2.2 x 2.5m
■ Shield Characteristic :
10kHz ~ 150kHz  : > 100dB(Electric field)
150kHz ~ 30MHz  : > 100dB(Electric field)   : >   70dB(Magnetic field)
30MHz ~ 1GHz  : > 100dB(Plane wave)
1GHz ~ 10GHz  : >   90dB(Plane wave)
10GHz ~ 18GHz  : >   80dB(Plane wave)

 ■ Chamber Specification
Size   : 1000 x 1000 x 800mm
Temp : -65℃ ~ +180℃
Humi : 10%RH ~ 95%RH
*G-TEM Cell : Septum : 750mm
(10kHz – 4GHz/200V/m)
■ Standards
ISO 7637-2 / ISO 7637-3
ISO / TR 10605 / ISO 10605
ISO 11452-3
EN 301 489-1,3,17
EN 61000-3-2,3
EN 61000-4-2,4,5,6,8,11

Testing Devices for in-vehicle products

■ 50Ω Strip line

■ Tri-plate

■ TEM Cell

■ G-TEM Cell

Environment Test Facilities

Vibration Testing Room

Vibration Test Part

■ Exciting Force:
Sine Force: 35.0 kN
Random Force: 35.0kNrms
Shock Force: 87.5kN

■ Max. Displacement: 60 mmp-p

■ Max. Velocity: 2 m/s

■ Frequency Range: DC ~ 2200 Hz

■ No-load Maximum Acceleration :
Sine: 1000.0 m/s2
Shock: 1470 m/s20-P

Chamber Part

■ Temperature: – 40 ~ +150℃

■ Humidity: 30 ~ 98%RH

Waterproof Testing Room

Waterproof Test Equipment

■ Water Drop Test: IPX1, IPX2

■ Water Spray Test: IPX3, IPX4

■ Water Jet Test:

IPX5, IPX6, IPX6k

■ Compliance Standards

・ IEC 60529

・ JIS D 5020

Dustproof Testing Room

Dustproof Test Equipment

■ Internal Dimension:

800x 1000 x 900mm

■ Capacity: 20kg or less

■ Dust: Talc Powder

■ Compliance Standards

・ IEC 60529

Interoperability Test Facilities

Interoperability Testing Room

■ Connectivity Tests

■ Functionality & Usability Tests

Besides Japan, field tests are possible in the following four countries.

■ USA

■ UK (EU)

■ China

■ Korea

Got a question? Want to know more about the service we offer?

Our team of advisers are here to help.Complete the contact form and we’ll get back to you.
CONTACT US
ATC Main page
By | 2017-12-22T00:04:54+00:00 July 24th, 2017|その他|Comments Off on Facility details at ATC

About the Author: